Data note

An eight-GPU node costs $4,729 a year in electricity at 700 W per card

Board-level power from the vendor spec sheets multiplied into annual kilowatt hours, then priced at the three U.S. average rates published for August 2026.

Verified answer checked

Eight boards at 700 W draw 5.6 kW, which is 49,056 kWh over 8,760 hours, and at the U.S. average industrial price of 9.64 cents per kWh that is $4,729.00 a year. Eight boards at 750 W draw 6.0 kW, which is 52,560 kWh and $5,066.78, a difference of $337.79 (calculated 2026-11-15).

  • NVIDIA prints a maximum thermal design power of up to 700 W for both H100 and H200, configurable (checked 2026-11-15).
  • AMD prints 750 W typical board power for MI300X (checked 2026-11-15).
  • EIA's August 2026 table gives U.S. average prices of 9.64 cents per kWh for industrial, 14.47 cents for commercial and 18.16 cents for residential customers (checked 2026-11-15).
  • Eight boards at 700 W draw 5.6 kW, which is 49,056 kWh over 8,760 hours; eight boards at 750 W draw 6.0 kW, which is 52,560 kWh (calculated 2026-11-15).
  • At 9.64 cents per kWh the 700 W node costs $4,729.00 a year and the 750 W node costs $5,066.78, a difference of $337.79 (calculated 2026-11-15).
  • The same 700 W node costs $7,098.40 a year at the commercial rate and $8,908.57 at the residential rate (calculated 2026-11-15).

3 primary sources · If this is out of date, tell us and we will re-measure.

On this page
  1. What the pages print
  2. The arithmetic
  3. Where the bill really goes
  4. What the number is good for
  5. How we verified this

Board power is the one number every accelerator page prints, and it is the only input needed to reach an annual electricity bill. Multiply it by the number of boards, by the hours in a year, and by a published price per kilowatt hour. The result is the number nobody puts in a datasheet.

Two ceilings matter here: 700 W for NVIDIA's H100 and H200, and 750 W typical board power for AMD's MI300X. Both are printed on the vendor pages. The price side comes from the U.S. Energy Information Administration's table of average electricity prices by end-use sector.

What the pages print

NVIDIA lists a maximum thermal design power of up to 700 W, configurable, on both the H100 and H200 pages. AMD lists 750 W typical board power for MI300X. Those labels describe the board, not the node, and not the facility.

EIA's August 2026 table gives U.S. average prices per kilowatt hour of 18.16 cents for residential customers, 14.47 cents for commercial, 9.64 cents for industrial, and 14.87 cents across all sectors. Three of those four rows are used below, because a machine drawing more than five kilowatts is priced like a factory rather than a household.

The arithmetic

Eight boards at 700 W is 5,600 W, or 5.6 kW. Over 8,760 hours that is 49,056 kWh. At 9.64 cents that is $4,728.9984, which rounds to $4,729.00.

Eight boards at 750 W is 6,000 W, or 6.0 kW, which is 52,560 kWh a year. At the same rate that is $5,066.784, or $5,066.78. The gap between the two nodes is 3,504 kWh, or $337.79 a year.

The sector rate matters more than the 50 W board difference. The same 700 W node costs $7,098.40 at the commercial rate and $8,908.57 at the residential one.

ItemValueWhere it comes from
H100 / H200 power ceilingup to 700 W, configurableNVIDIA spec tables
MI300X power750 W typical board powerAMD spec table
Industrial price9.64 cents per kWhEIA Table 5.6.A, U.S. Total
Commercial price14.47 cents per kWhEIA Table 5.6.A, U.S. Total
Residential price18.16 cents per kWhEIA Table 5.6.A, U.S. Total
700 W node, annual energy49,056 kWh5.6 kW × 8,760 h (calculated 2026-11-15)
750 W node, annual energy52,560 kWh6.0 kW × 8,760 h (calculated 2026-11-15)
700 W node at industrial$4,729.00 a year49,056 kWh × $0.0964 (calculated 2026-11-15)
750 W node at industrial$5,066.78 a year52,560 kWh × $0.0964 (calculated 2026-11-15)
Difference$337.79 a yearderived from the two rows above (calculated 2026-11-15)

Where the bill really goes

The 50 W board difference is the small term. Moving from an industrial tariff to a commercial one adds $2,369.40 to the same node, and the residential tariff adds $4,179.57. Choosing a power contract is worth more than choosing between a 700 W and a 750 W board.

Utilization is the other term that swamps everything else. The arithmetic assumes 8,760 hours at the printed ceiling. A node that sits idle for half the year pays about half of that, and a node run below its configurable ceiling pays in proportion to the draw it reaches.

Facility overhead is deliberately absent. Cooling, power distribution losses and the host CPUs are all outside the 5.6 kW, which is why a metered rack costs more than $4,729.00 for the same eight accelerators.

What the number is good for

A figure like $4,729.00 a year is a floor for planning, not a quote. It answers one question precisely: how much does the accelerator silicon cost to keep powered at its printed ceiling, at a published average rate, with nothing else on the node.

That is enough to compare two configurations, and it is enough to see which term dominates. Two boards 50 W apart move the bill by $337.79. One tariff step moves it by thousands. Those are different orders of magnitude, and operators who spend their attention on the board choice rather than the power contract are optimising the small term.

For anything beyond that comparison, the honest answer is a metered number from the facility. Metered draw already includes the CPU, the fans, the losses, the idle hours and the real tariff, none of which appears in the arithmetic above.

How we verified this

The two power labels and the four price rows were read from the vendor pages and the EIA table on 2026-11-15. Every other number in this piece comes from multiplying those rows, so each appears marked calculated while the inputs appear marked checked.

Two caveats belong next to the figure. The vendor labels are ceilings and typical values rather than metered draws, and the EIA numbers are state-averaged prices for one month, not the rate any particular operator negotiates.

Frequently asked questions

What is included in this annual figure?

Only the eight accelerator boards. The host CPU, system memory, network cards, fans, power supply losses and any facility cooling sit outside the 5.6 kW, so a metered rack is always higher than $4,729.00 (calculated 2026-11-15).

Why use the industrial rate and not the residential one?

Because a node that draws 5.6 kW is not plugged into a house. The industrial average for August 2026 is 9.64 cents per kWh against 18.16 cents residential, and at the residential rate the same node costs $8,908.57 a year (calculated 2026-11-15).

Does utilization change the answer?

It changes it completely. The arithmetic assumes the boards sit at the printed ceiling for all 8,760 hours. A node that idles half the year pays roughly half, and a node that runs below its configurable ceiling pays in proportion to the draw it actually reaches.

Is the 700 W figure a measurement?

No. Both pages call it a maximum thermal design power that is configurable, which is a ceiling the board can be set to rather than a metered wall draw (checked 2026-11-15).

Sources

  1. NVIDIA H100 Tensor Core GPUMaximum thermal design power of up to 700 W, configurable; read 2026-11-15
  2. AMD Instinct MI300X750 W typical board power; read 2026-11-15
  3. EIA Electric Power Monthly, Table 5.6.AU.S. Total average price by end-use sector, August 2026: 18.16 residential, 14.47 commercial, 9.64 industrial, 14.87 all sectors, cents per kWh; read 2026-11-15

Cite this page

Nadia Voss (2026). “An eight-GPU node costs $4,729 a year in electricity at 700 W per card”. Actual Database. https://actualdatabase.com/eight-gpu-node-power-cost-per-year/

Written and verified by

Nadia Voss · Data researcher

I collect prices, limits and quotas from primary sources, date every figure, and re-check them on a fixed schedule. No sponsored placements inside a table, ever.